describe
Model | Sensor without system plug |
Application | Indoor |
Protective field range | 7 m |
Warning field range | 49 m (20 m at 20 % reflectivity) |
Distance measuring range | 49 m |
Number of simultaneously monitored protective fields | ≤ 4 1) |
Type of field set | Triple field sets, dual field sets |
Number of field sets | 1 |
Number of fields | 4 2) |
Number of monitoring cases | 1 |
Scanning angle | 190° |
Resolution (can be configured) | 30 mm, 40 mm, 50 mm, 70 mm, 150 mm |
Angular resolution | 0.5°, 0.25°, depending on range and resolution |
Response time | 60 ms 3) |
Protective field supplement | 100 mm |
Number of multiple samplings | 2 … 16, configurable |
Delay of automatic reset | 2 s … 60 s, configurable |