describe
Measuring range | 50 mm … 12,000 mm, 90% remission factor 1) 2) 50 mm … 5,300 mm, 18 % remission 50 mm … 3,100 mm, 6% remission factor | ||||||
Target | Natural objects | ||||||
Resolution | 0.1 mm | ||||||
Repeatability | ≥ 0.5 mm 2) 3) 4) | ||||||
Measurement accuracy | Typ. ± 10 mm 4) | ||||||
Response time | 4.5 ms … 192.5 ms, 4.5 ms / 12.5 ms / 24.5 ms / 48.5 ms / 192.5 ms 5) 6) | ||||||
Switching frequency | 166 Hz/50 Hz/25 Hz/12 Hz/3 Hz 5) 6) | ||||||
Output time | 2 ms … 64 ms, 2 ms/4 ms/8 ms/16 ms/64 ms 5) 7) | ||||||
Light source | Laser, red 8) visible red light | ||||||
Type of light | Visible red light | ||||||
Laser class | 1 (IEC 60825-1:2014, EN 60825-1:2014) | ||||||
Typ. light spot size (distance) | 15 mm x 15 mm (at 2 m) | ||||||
Additional function | Set speed: Super Fast … Super Slow Teach-in of analog output and invertible analog output Output Q2 adaptable: Current output / Voltage output / Digital output Switching mode: Distance to Object (DtO) / switching window / object between sensor and background (ObSB) Teach-in of digital output and digital output invertible Multifunctional input: laser off / external teach / deactivated Reset to factory default | ||||||
Average laser service life (at 25 °C) | 100,000 h | ||||||
|